The LCI-90i-IS Hazardous Location Display is a new, next-generation rugged programmable controller that combines advanced signal-processing capabilities with the rugged reliability that made the original LCI-90 display a popular choice for new winch projects and retrofits of existing line monitoring equipment. Versions of the UL Approved Class 1, Division 2 Rugged Programmable Controller are available for winch, pump, crane, tank, and torque applications.
Five fully-sealed pushbuttons within a heavy- duty 316 stainless steel front panel access an easy-to-follow English language menu for field calibration changes, I/O channel configuration, alarm settings, network settings, and screen layout – all intuitive and right at your fingertips.
Sensor data, parameters, alarms, controls and graphs are displayed on a bright 320x240 electroluminescent display for unmatched 160° readability in all light conditions. Four I/O channels, serial networking capability, plus USB and Ethernet ports provide flexibility in line monitoring, weighing, or SCADA applications. An internal CF disk permits on-board data logging, and the LCI-90i-IS can be linked with remote displays to create a real-time monitoring network.
General Specifications | Instrument Specifications | ||
---|---|---|---|
Power |
0.75 Amp @ 9-36 VDC Isolated, surge protected |
Analog Input |
4 channels 4-20 mA, 0-5, 0-10 VDC, mv/v |
Enclosure Size | H 5.7" x W 7.6" x D 5.0" | Count Input |
4 channels Quadrature x1, x2, x4 Count/Direction Up/Down counter 10 kHz Bandwidth |
Operating Temperature | -40°C to 75°C standard | Digital I/O |
4 Channels, isolated Opto Isolated |
Environmental |
Waterproof front panel Watertight rear enclosure or console available |
Serial Communications |
RS-485, isolated, half-duplex RS-232, non-isolated Ethernet, 10 Base-T TCP/UDP |
- US/CN UL certified for Class 1, Division 2, Groups A,B,C,D, T5 Hazardous Locations
- 320 x 240 EL (Electroluminescent) Display Readable In All Conditions
- Full programmability via English language menus.
- Six alarms, independently linked to any high/low setpoint parameters.
- Configurable parameter position, scale, and units.
- Network configurable.
- Three modes of analog sensor calibration.
- On screen calibration, diagnostics, and configuration security.
- Watertight enclosure & mount available.